7×7 Galvanised Steel Wire Rope G2070 Specifications

7×7 Galvanised Steel Wire Rope G2070 Specifications

7×7 Galvanised Steel Wire Rope G2070 Specifications is a table outlining the Minimum Breaking Strain of 7×7 Galvanised Steel Wire Rope. Minimum Breaking Strain (MBS) is also known as the Minimum Breaking Load (MBL). In calculating the MBS, the load is applied along the length of the wire. If the load is applied perpendicular to the wire, the MBS is divided by a factor of 2.

7X7 Galvanised Steel Wire Structure
7X7 Galvanised Steel Wire Structure

MBS

The Minimum Breaking Strain is related to the Maximum Working Load and is the stated minimum ‘strength’ of the wire rope. This load represents a mass or force that is required to make the wire rope fail or yield, also known as the Minimum Breaking Strain (MBS). SWL or WLL are calculated by dividing the MBL by a safety factor (SF).

SWL

The Safe Working Load (SWL) is a common but outdated term (See “What is the Safe Working Load SWL?” post in our Advice section). The currently correct term is the Working Load Limit or WLL. SWL or WLL are calculated by dividing the MBS by a safety factor (SF) and the SF varies by application or project. Often it will be specified by the design engineer.

Low Cost Wire recommends a 10x SF if the lifting element (wire in this case) holds an object above ‘people’ and a 5x SF if the object is above ‘things’ and could never injure a person in the event of a catastrophic failure. The table below presents the WWL of the wire with a 10x SF when the suspended weight is held by wire in a Vertical Orientation or in a Horizontal Orientation.

Please NOTE: The dimensions and specifications of our products that we quote on this page and on every other page on this website are intended to be used for reference only. When product dimensions or specifications are important to your application, please contact us for assistance. If the specifications are critical – then undertaking Proof and Destruction Tests are HIGHLY recommended.

For critical load specifications, Low Cost Wire recommend that you confirm all relevant details before ordering as information may change without prior notice.

Diameter

 Structure 

 Grade 

 MBS* (kN) 

 MBS (kg)
(approx)
WLL
(kg)
(vertical)
WLL
(kg)
(horizontal)
3.0mm 7×7 2070 6.7 632.2 63.2 31.6
3.2mm
(1/8″)
7×7 2070 7.0 713.8 71.4 35.7
3.5mm 7×7 2070 8.4 856.6 85.7 42.8
4.0mm
(5/32″)
7×7 2070 11.0 1121.7 112.2 66.1
4.8mm
(3/16″)
7×7 2070 15.8 1611.2 161.1 80.5
5.0mm 7×7 2070 17.1 1743.7 174.4 87.2
6.0mm 7×7 2070 24.7 2518.7 251.9 125.9
6.4mm
(1/4″)
7×7 2070 27.3 2783.8 278.4 139.2
8.0mm
(5/16″)
7×7 2070 43.9 4476.6 447.7 223.8